Page #544 background imageLoading...
Page #544 background image
Administration and Provisioning
8-140 Issue 8.0 July 2002
The User Privilege parameter sets the user's security level for
nonprivileged users to either:
—“Reports Only: User will be able to execute only the
Retrieve, Set-Password, and Test-LED inputs.
—“General: User will be able to execute all commands, except
Initialize-System, Set-Login, Set-Network Element, and
Set-Security.
The Status parameter for a privileged user can only be set to
"Enabled."
SECURITY-Set-Login-Delete: This input deletes a nonprivileged login.
If the login is active at the time this command is executed, the user is
immediately logged off the system.
The Login parameter selects the login that is to be deleted. The
Retrieve-Login input will list the login IDs.
SECURITY-Set-Login-Enter: This input enters a new login, including
password and user privileges. A privileged user can create up to 10
nonprivileged logins per network element.
There are 2 privileged user IDs and up to 10 nonprivileged IDs allowed per
network element.
The New Login parameter is the login ID for the login being created.
It must be a string of from 1 to 10 alphanumeric characters, in which
the difference between upper and lower case is significant, and it
must be different from all other login IDs in this network element.
The New Password parameter is the password for the login being
created. A password consists of a string of alphabetic, numeric, or
symbolic characters conforming to the following rules:
String must contain from 6 to 10 characters
At least 2 of the characters must be nonalphabetic
At least 1 of the characters must be symbolic (the @, #, ?, or
space not allowed)
The difference between upper and lower case is significant.
The Re-enter New Password parameter confirms the New
Password. Reenter the exact characters that were entered for the
New Password parameter.
The User Privilege parameter sets the user's security level to one of
the following:
"Reports Only": User will be able to execute only the
Retrieve
, Set-Password, and Test-LED inputs.
"General": User will be able to execute all commands, except
Initialize-System, Set-Login
, Set-Network Element, and
Set-Security.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish