Craft Interface Terminal Usage
11-78 Issue 8.0 July 2002
Release 2 (Use the FAULT category.)
The above report shows the alarm and status conditions that are currently being
reported within the FT-2000 network. If no alarms exist in the FT-2000 network, a
report is generated that states, "There are no active alarms or status
conditions."
System Alarm - Shows the highest system alarm at each FT-2000 network
element. The alarm corresponds to the topmost user panel
LED that is lit at an FT-2000 network element or the alarm
level reported by the FT-2000 repeater bay/shelf.
Date Time
Detected
- Shows the date in month and day, and the time in hours,
minutes, and seconds for each event when it was first
reported.
Source
Address
- Shows the remote FT-2000 end terminal identification (TID) or
the FT-2000 repeater bay/shelf site address.
Event
Description
- Shows an alarm condition summary for the repeater bay/shelf.
No
Event Description
is provided for an FT-2000 end terminal.
Delta-1 93-01-19 23:15:15 EST
M Retrieve-Network Alarms: COMPLD
/* Network Alarms Report
==========================================================================
System Date Time Source Event
Alarm Detected Address Description
==========================================================================
CR 03-26 18:35:10 TID-of-near-end-NE
__________________________________________________________________________
MJ 03-26 18:36:02 site-p-01 repeater bay equipment failure
__________________________________________________________________________
MN 03-26 18:36:28 site-1-03 incoming OC48 B1 parity error
MN 03-26 18:36:51 TID-of-far-end-NE
*/
;