Craft Interface Terminal Usage
11-104 Issue 8.0 July 2002
The fields of the report are described below:
Address - Shows the path name including the line, slot or tributary, and
port.
Start Time - Shows the time in hours and minutes (quarter-hour
increments) that data collection started. But if month and day
are shown, the data is for yesterday.
CV-P - Shows the number of code violations reported in the bin
during the specified time that will cause a TCA.
ES-P - Shows the number of errored seconds reported in the bin
during the specified time that will cause a TCA.
SES-P - Shows the number of severely errored seconds reported in
the bin during the specified time that will cause a TCA.
UAS-P - Shows the number of unavailable seconds reported in the bin
during the specified time that will cause a TCA.