Craft Interface Terminal Usage
Issue 8.0 July 2002
11-105
Release 3
The above report (can be a multiple page report) shows the current STS-1 path
performance-monitoring data for an electrical low-speed signal on line 1, slot 1,
ports 1, 2, and 3. When a greater than sign (">") is displayed, it means the
violations are greater than the maximum value for the parameter. When a
question mark (?) is displayed, it means corrupted data or an incomplete time
cycle for that parameter. When a hyphen ("-") is displayed, it means the data is
unavailable, such as any port in the NMON or AUTO state. This report is not
available at the repeater site.
TERMB 92-07-15 13:15:15 EST
M Retrieve-Performance Monitoring-STS1:1-1-All: COMPLD
/* STS-1 Path Performance Monitoring Status Report
Last initialized: quarter hour registers at 92-07-15 13:15:00
day registers at 92-07-15 00:00:00
================================================================
Address Start B3 B3 B3 B3
Time CV ES SES UAS
================================================================
sts1-1-1-1 Today 5 1 0 0
----------------------------------------------------
13:15 0 0 0 0
09:00 5 1 0 0
================================================================
sts1-1-1-2 Today 0 0 0 0
----------------------------------------------------
13:15 0 0 0 0
================================================================
sts1-1-1-3 Today 0 0 0 0
----------------------------------------------------
13:15 0 0 0 0
*/
;