The fields of the report are described below:
Address - Shows the path name including the line, slot or tributary,
and port.
Start Time - Shows the time in hours and minutes (quarter-hour
increments) that data collection started. But if month
and day are shown, the data is for yesterday.
B3 CV - Shows the number of code violations reported in B3
during the specified time.
B3 ES - Shows the number of errored seconds reported in B3
during the specified time.
B3 SES - Shows the number of severely errored seconds reported
in B3 during the specified time.
B3 UAS - Shows the number of unavailable seconds reported for
path during the specified time.