Craft Interface Terminal Usage
11-108 Issue 8.0 July 2002
The fields of the report are described below:
Address - Shows the address within the FT-2000 end terminal; for
example, low-speed shelf, line 1, slot 1b, and port 1. The
address for an FT-2000 add/drop-rings terminal would
show the low-speed shelf, slot, and port.
Start Time - Shows the time in hours and minutes (quarter-hour
increments) that data collection started.
ES-L - Shows the number of errored seconds reported in the bin
during the specified time that will cause a TCA.
CV-P - Shows the number of code violations reported in the bin
during the specified time that will cause a TCA.
ES-P - Shows the number of errored seconds reported in the bin
during the specified time that will cause a TCA.
SES-P - Shows the number of severely errored seconds reported in
the bin during the specified time that will cause a TCA.
SAS-P - Shows the number of severely errored frame/AIS seconds
reported in the bin during the specified time that will cause
aTCA.
UAS-P - Shows the number of unavailable seconds reported in the
bin during the specified time that will cause a TCA.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish