Craft Interface Terminal Usage
Issue 8.0 July 2002
11-109
Release 3
The above report, which can be a multiple page report, shows the current
performance-monitoring data for a T3 (address a DS3 port). This report is the
same in a point-to-point network and a ring network except the address (after T3:)
is different. When a greater than sign (">") is displayed, it means the violations are
greater than the maximum value for the parameter. When a question mark ("?") is
displayed, it means corrupted data or an incomplete time cycle for that parameter.
When a hyphen ("-") is displayed, it means the data is unavailable, such as any
port in the NMON or AUTO state. This report is not available at the repeater site.
Address - Shows the address within the FT-2000 end terminal; for
example, low-speed shelf, line 1, slot 1b, and port 1. The
address for an FT-2000 add/drop-rings terminal would show
the low-speed shelf, slot, and port.
Start Time - Shows the time in hours, minutes, and seconds.
PCV - Shows the number of performance code violations.
TERMB 91-07-15 23:15:15 EST
M Retrieve-Performance Monitoring-T3:1-1B-1: COMPLD
/* DS-3 Performance Monitoring Status Report
Last initialized: quarter hour registers at 91-07-15 23:15:00
day registers at 91-07-15 00:00:00
==================================================================
Address Start P CV
Time
==================================================================
ls-1-1b-1 Today 65535>
07-14 20
------------------------------------------------------------------
23:15 0
16:00 65535>
15:45 3
15:30 9
*/
;