EasyManuals Logo

Lucent Technologies FT-2000 OC-48 User Manual

Lucent Technologies FT-2000 OC-48
1578 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #834 background imageLoading...
Page #834 background image
Craft Interface Terminal Usage
11-126 Issue 8.0 July 2002
The fields of the report are described below:
Address - Shows the specific DS3 low-speed slot and port.
Bin - Shows the quarter-hour (QH) and the day bins.
DS3 Line
ES-L
- Shows the provisioned number of line errored seconds for
the QH and day bins that will cause a TCA.
BER - Shows the provisioned bit error rate for the QH and day bins
that will cause a TCA.
CV-P - Shows the provisioned number of code violations for the QH
and day bins that will cause a TCA.
ES-P - Shows the provisioned number of errored seconds for the QH
and day bins that will cause a TCA.
SES-P - Shows the provisioned number of severely errored seconds
for the QH and day bins that will cause a TCA
SAS-P - Shows the provisioned number of severely errored frame/AIS
seconds for the QH and day bins that will cause a TCA.
UAS-P - Shows the provisioned number of unavailable seconds for
the QH and day bins that will cause a TCA.
TCA Report - Shows if the automatic reporting of TCAs is enabled or
disabled.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish