Craft Interface Terminal Usage
Issue 8.0 July 2002
11-129
Release 3 (Use the CONFIGURATION category.)
The above report shows the provisioned protection switching information of the
FT-2000 add/drop-rings terminal.
Operating
Mode
- Shows the add/drop-rings terminal configuration and whether
protection switching is unidirectional or bidirectional.
Wait To
Restore
- Shows the time (up to 12 minutes after a trouble clears)
before breaking automatic high-speed, low-speed, and
synchronization reference protection switches.
Delta-1 93-01-19 23:15:15 EST
M Retrieve-Protection-Line: COMPLD
/* Network Element Protection Switching Provisioning Report
=============================================================
Parameter Value
=============================================================
Operating Mode 2 fiber ring bi-directional
Wait To Restore 0 (disabled)
*/
;