Craft Interface Terminal Usage
11-130 Issue 8.0 July 2002
Release 2 (Use the CONFIGURATION category.)
The above report shows the provisioned protection switching information for the
near-end FT-2000 terminal.
Operating
Mode
- Shows the current operating protection switching
configuration (1x1 or 1+1) and the direction (bidirectional or
unidirectional).
Wait To
Restore
- Shows the time in minutes to wait after a trouble clears
before dropping the automatic protection switches (both
low-speed and high-speed).
Restoration
Protection
Access
- Shows the parameter value (either yes or no) if the FT-2000
terminal is provisioned for restoration protection access.
TERMB 92-01-19 23:15:15 EST
M Retrieve-Protection-Line: COMPLD
/* Network Element Protection Switching Provisioning Report
=============================================================
Parameter Value
=============================================================
Operating Mode 1x1 bi-directional
Wait To Restore 5 minutes
Restoration Protection Access no
*/
;