365-575-102 Acceptance:
Issue 8.0, July 2002 Page 1 of 4
NTP-002
Accept FT-2000 OC-48 1x1 End Terminal
DO ITEMS BELOW IN ORDER LISTED . . . . . . . FOR DETAILS, GOTO
1. Overview: This acceptance procedure tests an out-of-service FT-2000
1x1 End Terminal in a stand-alone state. Each FT-2000 end terminal in
the FT-2000 point-to-point network should be tested individually.
Required Test Equipment:
Craft Interface Terminal (CIT)
Optical Loopback Jumpers with 20-dB buildout
Wrist Strap
!
WARNING:
Unterminated optical connectors may emit invisible laser radiation.
Eye damage may occur if beam is viewed directly or with improper
optical instruments. Avoid direct exposure to beam.
!
CAUTION:
Use a static ground wrist strap whenever handling circuit packs or
working on an FT-2000 end terminal to prevent electrostatic
discharge damage to sensitive components. See "Electrostatic
Discharge (ESD) Considerations" in Trouble Clearing: TAD-100.
NOTE:
This procedure is only used if the FT-2000 end terminal was installed
by someone else. If the installation has not been completed
(including circuit pack installation), notify the installation personnel or
refer to 365-575-104 to complete the installation. If you completed
the installation following the procedures in 365-575-104, do not
perform this procedure.
NOTE:
It is assumed that installation of the FT-2000 end terminal has been
completed (including circuit pack installation) for the engineered
configuration. It is further assumed that the end terminal is powered
and running.
If at any point in this procedure, the FT-2000 end
terminal fails to respond in the indicated way, refer the trouble to
installation personnel.