365-575-102 Acceptance: NTP-003
Issue 8.0, July 2002 Page 1 of 4
Accept FT-2000 Point-to-Point Network
DO ITEMS BELOW IN ORDER LISTED . . . . . . . FOR DETAILS, GO TO
1. Overview: This acceptance procedure is made on the FT-2000
point-to-point network after all FT-2000 network elements (including any
repeaters) have been individually acceptance tested.
Required Test Equipment:
Craft Interface Terminal (CIT)
Wrist Strap
Optical Power Meter and/or Optical Time Domain Reflectometer
(OTDR) (Used in DLP-506)
!
WARNING:
Unterminated optical connectors may emit invisible laser radiation.
Eye damage may occur if beam is viewed directly or with improper
optical instruments. Avoid direct exposure to beam.
!
CAUTION:
Use a static ground wrist strap whenever handling circuit packs or
working on an FT-2000 network element to prevent electrostatic
discharge damage to sensitive components. See "Electrostatic
Discharge (ESD) Considerations" in Trouble Clearing: TAD-100.
NOTE:
This procedure is only used if the FT-2000 point-to-point network was
installed by someone else. If the installation has not been completed,
notify the installation personnel or refer to 365-575-104 to complete
the installation. If you completed the installation following the
procedures in 365-575-104, do not perform this procedure.
Each FT-2000 network element should have been individually acceptance
tested. If this has not been done, refer to Acceptance: NTP-002 for the
FT-2000 end terminal and/or refer to Acceptance: NTP-005 for the
FT-2000 repeater bay/shelf. If at any point in this procedure, an FT-2000
network element fails to respond in the indicated way, refer the trouble to
the group that installed it.