365-575-102 Acceptance: NTP-005
Issue 8.0, July 2002 Page 1 of 2
Accept FT-2000 OC-48 Repeater Bay/Shelf
DO ITEMS BELOW IN ORDER LISTED . . . . . . . FOR DETAILS, GO TO
1. Overview: This acceptance procedure tests an out-of-service FT-2000
repeater bay/shelf. Each FT-2000 repeater bay/shelf in the FT-2000 network
should be tested individually.
Required Test Equipment:
Craft Interface Terminal (CIT)
Optical Loopback Jumpers with 20-dB buildout
Wrist Strap
!
WARNING:
Unterminated optical connectors may emit invisible laser radiation. Eye
damage may occur if beam is viewed directly or with improper optical
instruments. Avoid direct exposure to beam.
!
CAUTION:
Use a static ground wrist strap whenever handling circuit packs or working
on an FT-2000 repeater bay/shelf to prevent electrostatic discharge
damage to sensitive components. See "Electrostatic Discharge (ESD)
Considerations" in Trouble Clearing: TAD-100.
NOTE:
This procedure is only used if the FT-2000 repeater bay/shelf was installed
by someone else. If the installation has not been completed (including
circuit pack installation), notify the installation personnel or refer to
365-575-104 to complete the installation. If you completed the installation
following the procedures in 365-575-104, do not perform this procedure.
NOTE:
It is assumed that installation of the FT-2000 repeater bay/shelf has
been completed (including circuit pack installation) for the engineered
configuration. It is further assumed that the repeater bay/shelf is
powered and running. If at any point in this procedure the FT-2000
repeater bay/shelf fails to respond in the indicated way, refer the
trouble to installation personnel.