NTP-006: Acceptance 365-575-102
Page4of6 Issue8.0,July2002
11. Use FAULT-Retrieve-Alarm to obtain an Active
Alarm and Status Report. Make a note of any
conditions other than those listed below that appear
in the report. (Your report may not include all of the
conditions listed.) Report these conditions to
installation personnel if any failures occur during the
following test.
system ring incomplete/open
system ring startup in progress
system DS-NE not reachable
system squelch map conflict
dcc-1e incoming DCC failure
dcc-1w incoming DCC failure
line-1e site provisioning conflict
line-1w site provisioning conflict
NOTE:
This test may be denied if the terminal is
exhibiting conditions or alarms other than those
listed here. The disallowed condition must be
cleared before continuing.
—
12. Perform local automatic turnup test for all lines. DLP-502
13. Use FAULT-Retrieve-Alarm to obtain an Active
Alarm and Status Report. Make a note of any
conditions, other than those listed in Step 11, that
appear in the report. (Your report may not include all
of the conditions listed.) Report these conditions to
installation personnel if any failures occur during the
following test.
—
14.
NOTE:
Only 2-way cables (input and output) can be tested.
Perform automatic low-speed cabling test ( to
cross-connect panel) for all low-speed ports.
DLP-503
DO ITEMS BELOW IN ORDER LISTED . . . . . . . FOR DETAILS, GO TO