NTP-008: Acceptance 365-575-102
Page2of2 Issue8.0,July2002
Acceptance: NTP-008---+---TAD-100
|---DLP-501
|---DLP-503
3.
If the automatic low-speed cabling test is accidentally performed on an
in-service low-speed cable, service will be interrupted.
Only 2-way cables (input and output) can be tested.
Perform automatic low-speed cabling test for all
added electrical low-speed cables.
DLP-503
4. At the CIT, select CONFIGURATION-Retrieve-
Alarm to obtain the Active Alarm and Status Report
and verify that there are no active alarms or status
conditions. Section 11 shows example of report.
5. The added electrical low-speed cables have passed
the acceptance tests and are ready for service.
—
DO ITEMS BELOW IN ORDER LISTED . . . . . . . FOR DETAILS, GO TO