365-575-102 Acceptance:
Issue 8.0, July 2002 Page 1 of 4
NTP-011
Accept FT-2000 OC-48 Add/Drop-Rings Terminal for
Operation With an FT-2000 Lightwave Booster
Amplifier (FT-LBA)
DOITEMSBELOWINORDERLISTED....... FORDETAILS,GOTO
1. Overview: This acceptance procedure tests the four miscellaneous
discrete telemetry connections from an FT-Lightwave Booster
Amplifier (FT-LBA) to the FT-2000 terminal. It also verifies that the
appropriate text strings have been provisioned for these inputs at the
FT-2000 terminal. Additional descriptive information is in Section 6,
"User-Settable Miscellaneous Discrete Interface."
Required Test Equipment:
Craft Interface Terminal (CIT)
Wrist Strap
!
WARNING:
Unterminated optical connectors may emit invisible laser radiation.
Eye damage may occur if beam is viewed directly or with improper
optical instruments. Avoid direct exposure to beam.
!
CAUTION:
Use a static ground wrist strap whenever handling circuit packs or
working on an FT-2000 terminal to prevent electrostatic discharge
damage to sensitive components. See "Electrostatic Discharge (ESD)
Considerations" in Trouble Clearing: TAD-100.