NTP-010: Acceptance 365-575-102
Page2of2 Issue8.0,July2002
Acceptance: NTP-010---+---TAD-100
|---DLP-501
|---DLP-503
NOTE:
It is assumed that installation of the new optical low-speed fibers has been
completed (including associated circuit pack installation) for the engineered
configuration and that the FT-2000 network element is in service.
If at any
point in this procedure the FT-2000 add/drop-rings terminal fails to
respond in the indicated way, refer the trouble to installation
personnel.
If required, connect the craft interface terminal
(CIT) to the local FT-2000 network element and
condition it.
DLP-501
2. At the CIT, select FAULT-Retrieve-Alarm to obtain
the Active Alarm and Status Report (example is
shown in Section 11) and verify that there are no
active alarms or status conditions.
3.
!
CAUTION:
If the automatic low-speed cabling (fiber) test is accidentally performed on
an in-service low-speed fiber, service will be interrupted.
NOTE:
Only 2-way fibers (input and output) can be tested.
Perform automatic low-speed cabling (fiber) test
for all new optical low-speed fibers.
DLP-503
4. At the CIT, select FAULT-Retrieve-Alarm to obtain
the Active Alarm and Status Report (example is
shown in Section 11) and verify that there are no
active alarms or status conditions.
5. The new optical low-speed fibers have passed the
acceptance tests and are ready for service.
DO ITEMS BELOW IN ORDER LISTED . . . . . . . FOR DETAILS, GO TO