NTP-010: Acceptance 365-575-102
Page2of2 Issue8.0,July2002
Acceptance: NTP-010---+---TAD-100
|---DLP-501
|---DLP-503
NOTE:
It is assumed that installation of the new optical low-speed fibers has been
completed (including associated circuit pack installation) for the engineered
configuration and that the FT-2000 network element is in service.
If at any
point in this procedure the FT-2000 add/drop-rings terminal fails to
respond in the indicated way, refer the trouble to installation
personnel.
If required, connect the craft interface terminal
(CIT) to the local FT-2000 network element and
condition it.
DLP-501
2. At the CIT, select FAULT-Retrieve-Alarm to obtain
the Active Alarm and Status Report (example is
shown in Section 11) and verify that there are no
active alarms or status conditions.
—
3.
!
CAUTION:
If the automatic low-speed cabling (fiber) test is accidentally performed on
an in-service low-speed fiber, service will be interrupted.
NOTE:
Only 2-way fibers (input and output) can be tested.
Perform automatic low-speed cabling (fiber) test
for all new optical low-speed fibers.
DLP-503
4. At the CIT, select FAULT-Retrieve-Alarm to obtain
the Active Alarm and Status Report (example is
shown in Section 11) and verify that there are no
active alarms or status conditions.
—
5. The new optical low-speed fibers have passed the
acceptance tests and are ready for service.
—
DO ITEMS BELOW IN ORDER LISTED . . . . . . . FOR DETAILS, GO TO