365-575-102 CircuitOrder:
Issue 8.0, July 2002 Page 1 of 4
NTP-002
Add DS3 and/or EC1 Low-Speed Port(s)
DO ITEMS BELOW IN ORDER LISTED . . . . . . . . FOR DETAILS, GO TO
1. Overview: This procedure is used to add a low-speed port to a network element
and not to make cross-connections. Refer to DLP-536 for cross-connect
information for an FT-2000 OC-48 Add/Drop-Rings Terminal.
Required Test Equipment:
Craft Interface Terminal (CIT)
Wrist Strap
!
CAUTION:
Use a static ground wrist strap whenever handling circuit packs or working
on an FT-2000 terminal to prevent electrostatic discharge damage to
sensitive components. See "Electrostatic Discharge (ESD)
Considerations" in Trouble Clearing: TAD-100.
NOTE:
Shelves are keyed to prevent circuit packs from being accidentally installed
into the wrong slots.
NOTE:
This procedure may be performed after all installation wiring and testing of
the Low Speed Shelf - System Controller and/or the Low Speed Shelf -
Complementary have been completed or on an in-service basis. Additional
installation information is contained in 365-575-104,
FT-2000 OC-48
Lightwave System, Releases 1 and 2, Installation Manual
,andin
365-575-115,
FT-2000 OC-48 Lightwave System, Releases 3, 4, and 5,
Installation Manual
.
NOTE:
A DS3 (LAA2/LAA2B) or STS1E (LAA4) circuit pack has three ports.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish