365-575-102 CircuitOrder:
Issue 8.0, July 2002 Page 1 of 4
NTP-003
Delete DS3 and/or EC1 Low-Speed Port(s)
DOITEMSBELOWINORDERLISTED....... FORDETAILS,GOTO
1. Required Test Equipment:
Craft Interface Terminal (CIT)
Wrist Strap
!
CAUTION:
Use a static ground wrist strap whenever handling circuit packs or
working on an FT-2000 terminal to prevent electrostatic discharge
damage to sensitive components. See "Electrostatic Discharge (ESD)
Considerations" in Trouble Clearing: TAD-100.
NOTE:
A DS3 (LAA2/LAA2B) or STS1E (LAA4)
circuit pack has three ports.
Obtain the circuit order instructions to
delete a DS3 or EC1 port(s) and note the
assigned address. A point-to-point network
address requires a line, slot, and port(s)
assignment. A ring network address
requires a slot and port(s) assignment.
—
2. If required, connect and condition the craft
interface terminal (CIT).
DLP-501
3. If required by local operating procedures,
disconnect incoming signals and properly
terminate outgoing DS3 or EC1 signals at the
digital cross-connect bay, DACS III-2000, etc.,
for the port(s) being deleted.
DLP-520