365-575-102 CircuitOrder:
Issue 8.0, July 2002 Page 1 of 6
NTP-004
Delete OC-48 Protection Line From Point-to-Point
Network
DOITEMSBELOWINORDERLISTED....... FORDETAILS,GOTO
1. Required Test Equipment:
Craft Interface Terminal (CIT)
Wrist Strap
!
WARNING:
Unterminated optical connectors may emit invisible laser radiation. Eye
damage may occur if beam is viewed directly or with improper optical
instruments. Avoid direct exposure to beam.
!
CAUTION:
Use a static ground wrist strap whenever handling circuit packs or
working on an FT-2000 network element to prevent electrostatic
discharge damage to sensitive components. See "Electrostatic
Discharge (ESD) Considerations" in Trouble Clearing: TAD-100.
Obtain the circuit order instructions and
note which OC-48 line will be deleted.
—
2. If required, connect the Craft Interface Terminal
(CIT) to the local FT-2000 network element and
condition it.
DLP-501
3. Remove the appropriate high-speed shelf cover. DLP-511
4. Are you at an FT-2000 end terminal or FT-2000
repeater bay/shelf?
If FT-2000 end terminal, then continue with
Step 5.
If FT-2000 repeater bay/shelf, then continue
with Step 20.