192-121102 N04 June 2008 119
Object 172.3: IN0 Filter
Object name
C3Plus.AnalogInput0_FilterCoefficient
Object No. 172.3 HEDA-channel
no
Access:
Read/write
Valid after:
VP
CodeSys object:
yes
CodeSys format:
DINT
Unit
us
Minimum value
0 us
Maximum value
us
Remark:
CAN No.
-
PD object:
no
Profibus-No. (PNU)
-
Bus format:
I32
Object 173.11: IN1 Offset
Object name
C3Plus.AnalogInput1_Offset_normed
Object No. 173.11 HEDA-channel
no
Access:
Read/write
Valid after:
Immediately
CodeSys object:
yes
CodeSys format:
REAL
Unit
mA
Minimum value
mA
Maximum value
mA
Remark:
CAN No.
-
PD object:
no
Profibus-No. (PNU)
-
Bus format:
C4_3
Object 173.4: IN1 Offset
Object name
C3.AnalogInput1_Offset
Object No. 173.4 HEDA-channel
no
Access:
Read/write
Valid after:
Immediately
CodeSys object:
no
CodeSys format:
INT
Unit
Increments
Minimum value
n/a
Maximum value
n/a
Remark:
Offset in AD converter increments. Range 0..65535
CAN No.
-
PD object:
no
Profibus-No. (PNU)
-
Bus format:
I16
Object 173.3: IN1 Filter
Object name
C3Plus.AnalogInput1_FilterCoefficient
Object No. 173.3 HEDA-channel
no
Access:
Read/write
Valid after:
VP
CodeSys object:
yes
CodeSys format:
DINT
Unit
us
Minimum value
0 us
Maximum value
us
Remark:
CAN No.
-
PD object:
no
Profibus-No. (PNU)
-
Bus format:
I32