Setting up Compax3 C3F_T40
124 192-121102 N04 June 2008
Object 2250.13: P-term
Object name
C3Plus.PressureController_1_Proportional_Part_Kp
Object No. 2250.13 HEDA-channel
no
Access:
Read/write
Valid after:
VP
CodeSys object:
yes
CodeSys format:
REAL
Unit
%/pres
Minimum value
%/pres
Maximum value
%/pres
Remark:
CAN No.
-
PD object:
no
Profibus-No. (PNU)
-
Bus format:
I32
Object 2250.14: I-term
Object name
C3Plus.PressureController_1_Integration_Part_KFi
Object No. 2250.14 HEDA-channel
no
Access:
Read/write
Valid after:
VP
CodeSys object:
yes
CodeSys format:
REAL
Unit
%/(s pres)
Minimum value
0 %/(s pres)
Maximum value
4,000 %/(s pres)
Remark:
CAN No.
-
PD object:
no
Profibus-No. (PNU)
-
Bus format:
I32
Object 2250.15: Internal window I-term
Object name
C3Plus.PressureController_1_InsideWindow_IPart
Object No. 2250.15 HEDA-channel
no
Access:
Read/write
Valid after:
VP
CodeSys object:
yes
CodeSys format:
REAL
Unit
pres
Minimum value
pres
Maximum value
pres
Remark:
CAN No.
-
PD object:
no
Profibus-No. (PNU)
-
Bus format:
I32
Object 2250.16: External window I-term
Object name
C3Plus.PressureController_1_OutsideWindow_IPart
Object No. 2250.16 HEDA-channel
no
Access:
Read/write
Valid after:
VP
CodeSys object:
yes
CodeSys format:
REAL
Unit
pres
Minimum value
pres
Maximum value
pres
Remark:
CAN No.
-
PD object:
no
Profibus-No. (PNU)
-
Bus format:
I32