Clinical Applications
Introducing the IntelliVue Information Center System
1-31
Telemetry
Monitoring
The Information Center also displays patient data from Philips Digital Telemetry systems --
M1403A/J Digital UHF Telemetry system (software release E.00 and later) and M2600A
Philips Telemetry system. See Figure 1-20.
Note The Information Center can monitor up to 16 patients from two Philips telemetry mainframes
without a SCC. See Chapter 2, System Communications Controller.
\
The M1403A/J Telemetry system provides ECG monitoring of 2 ECG waves with the ability
to view up to 7 leads. M2600A Philips Telemetry provides ECG monitoring of 3 ECG waves
of up to 7 leads. The M2600A also provides SpO
2
measurements. ST Segment analysis is
P
(cont’d)
PAP Pulmonary Arterial Pressure PAP SYS Pulmonary Arterial Pressure - Systolic
PAP DIAS Pulmonary Arterial Pressure - Diastolic
PAP MEAN Pulmonary Arterial Pressure - Mean
AO Aortic Pressure AO SYS Aortic Pressure - Systolic
AO DIAS Aortic Pressure - Diastolic
AO MEAN Aortic Pressure - Mean
LAP Left Atrial Pressure LAP Left Atrial Pressure
RAP Right Atrial Pressure RAP Right Atrial Pressure
CVP Central Venous Pressure CVP Central Venous Pressure
ICP Intercranial Pressure ICP Intercranial Pressure
CPP Cerebral Profusion Pressure
NBP NBP SYS Non-invasive Blood Pressure - Systolic
NBP DIAS Non-invasive Blood Pressure - Diastolic
NBP MEAN Non-invasive Blood Pressure - Mean
CO CO Cardiac Output
Tblood Blood Temperature
CO
2
CO2 Carbon Dioxide AWRR Airway Respiration Rate
ETCO2 End tidal Carbon Dioxide
IMCO2 Inspired Minimum Carbon Dioxide
FIO
2
FIO2 Fractional Inspired oxygen
tcpO
2
/
tcpCO
2
tcp O2 Transcutaneous partial press. - O
2
tcp CO2 Transcutaneous partial press.- CO
2
SpO
2
/
Pleth
SpO2 Arterial oxygen saturation SpO2 Arterial oxygen saturation
PLETH Plethysmogram PULSE Pulse Rate
SvO
2
SvO2 Mixed venous oxygen saturation
T T Temperature
T1-T2 Temperature difference
Table 1-7. Information Center Patient Monitoring Capability
Philips
Module
Waves Parameters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Philips IntelliVue Series and is the answer not in the manual?

Philips IntelliVue Series Specifications

General IconGeneral
BrandPhilips
ModelIntelliVue Series
CategoryServer
LanguageEnglish

Related product manuals