218 ProSYS Installation and Programming Manual
EVENT MESSAGE DESCRIPTION
DAY B:P=X
Arm by scheduler of group B on partition X
DAY C:P=X
Arm by scheduler of group C on partition X
DAY D:P=X
Arm by scheduler of group D on partition X
DAY DIS:P=X
Daily Disarm on Partition X
DAY HOM:P=X
Daily Stay or Group Arming in Partition X
DC RESTORE
Z=XXX
DC trouble restore in BUS zone XXX
DC TROUBLE
Z=XXX
DC trouble in BUS zone XXX
DIS: P=X C=YY
Partition X disarmed by user YY
DIS:P=X WB=YY
Partition X disarmed by wireless keyfob YY
DOOR=XX:
AUTO
Door XX is defined to Automatic mode operation
DOOR=XX:
CLOSED
Door XX is defined to Always Closed mode operation
DOOR=XX:
OPEN
Door XX is defined to Always Open mode operation
DURESS C=XX
Duress alarm from user No. XX
DUST RST
Z=XXX
Dust trouble restore from WatchOUT DT BUS zone XXX
DUST Z=XXX
Dust trouble from WatchOUT DT BUS zone XXX
EE AC.UPLOAD
Load new parameters from PTM accessory
ELOG:COMM OK
Bus communication restore with event logger expander ID=X
ELOG:NO COMM
Bus communication failure with event logger expander ID=X
ENTER PROGRM
Entering Installer programming from keypad or UD software
EXIT PROGRAM
Exiting Installer programming from keypad or UD software
F.TR OK Z=XXX
Trouble restore in Fire zone XXX
F.TRBL Z=XXX
Trouble in Fire zone XXX
FALSE CODE
KP=XX
False code due to 3 incorrect keypad attempts
FALSE CODE
KR=XX
False code due to 3 incorrect Access Control attempts
FALSE
REST.KR=XX
False code is restored for key reader
FAULT Z=XXX
Trouble in zone XXX (TEOL zone or BUS zone input TEOL)
FIRE Z=XXX
Fire alarm in zone XXX
FIRE KP=XX
Fire alarm from keypad (ID=XX) (keys 3 & 4)
FOIL Z=XXX
Trouble in foil (Day) zone XXX
FOIL OK Z=XXX
Restore in foil (Day) zone XXX

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco ProSYS series and is the answer not in the manual?

Risco ProSYS series Specifications

General IconGeneral
CommunicationIP, GSM, PSTN
Wireless ProtocolTwo-way wireless
Battery BackupYes
Remote ControlYes, via app
IntegrationRISCO Cloud

Related product manuals