Operations and Maintenance Manual Universal Vacuum System
Version 1.2—March 2004 Page 25
PILOT PRESSURE
Adjust the regulator valve, below the pilot pressure gauge on the front control panel, until
the pressure is at the desired setting. Use the pilot pressure gauge to determine the actual
regulator pressure.
Goal
80 psi
PURGE PRESSURE
Adjust the regulator valve, below the purge pressure gauge on the front control panel, until
the pressure is at the desired setting. Use the purge pressure gauge to determine the actual
regulator pressure.
Goal
15-20 psi
DRAWINGS
Drawings specific to the Universal Vacuum System:
Drawing Number Title
289000T1 Configuration Tree (Options)
289000U1 Assembly Dimensions
289000U2 Center of Mass & Anchorage Loc.
289001A1 Elevation Drawings – Entire Machine
289001A2 Power Cabinet
289001A3 Control Panel
289001A4 Drain Tank
289001A5 Cabinet, Switch & Manifold
289001A6 Base Configuration
289001P1 System Configuration
289001E1 Electrical Schematic (110-120 VAC)
289001E2 Electrical Schematic (220-240 VAC)