STRASBAUGH, INC.
5-30 February 19, 2002 7AF SECS/GEM Interface Ver. 1.9
Strasbaugh Confidential
The message text will be displayed on the Equipment's CRT. Collection Event S10Ack (CEID 12) occurs once the
operator has acknowledged the message and an Event Report will be sent to the Host (if enabled).
The S10F3 and S10F9 are restricted to a single TEXT data item, but S10F5 can contain multiple TEXT data items. Each
TEXT data item is limited to 160 characters. Each data item in S10F5 will be displayed on a separate line at the
equipment.
If the Operator has not acknowledged an existing message when the Host sends another message, the new message will be
displayed and the old one discarded.
The Host can send a message with a 0-length text to clear the Operator text display.
Also, the Equipment allows the operator to send a single block message to the Host via S10F1. The maximum length of
this text is 160 characters. The S10F2 response from the Host is ignored.
5.10 Error Messages
The 7AF provides standard Stream 9 messages to report SECS-I errors. See 6.93, 6.94 and 6.95 of SECS Message Detail"
for detailed description of these messages:
S9F1 Unrecognized Device ID
S9F3 Unrecognized Stream
S9F5 Unrecognized Function
S9F7 Invalid Data
S9F9 Transaction Timeout
S9F11 Data Too Long
5.11 Clock
The 7AF contains Clock/Calendar hardware, by which it knows the current date and time.
The Host can send S2F31 to set the Equipment's Clock/Calendar hardware.
The Host can send S2F17 to read the Equipment's Clock/Calendar hardware.
The Operator can initiate a Date/Time request from the Host. The Equipment will send S2F17 to the Host and will set its
clock according to the data in the S2F18 reply.
Note that the Host generated command to update the clock will only be accepted when the Process State (VID 15) is “0”,
or when the operator is in the GEM Maintenance screen.
5.11.1 Related Variables
The following table lists the variables (SV's, EC's, or DVVALS) which are relevant to clock operation. For a more
complete description of these variables, see "Appendix A -- Variables".
Table 25 Clock Related Variables
Variable Name VID
CLOCK 237
TIME 243