STRASBAUGH, INC.
7AF SECS/GEM Interface Ver. 1.9 February 19, 2002 6-5
Strasbaugh Confidential
6-5
6.10 S1F14 - Connect Request Acknowledge
The Equipment sends this message using the following format:
S1F14 * H<-E
<L
<B [1] 00> * COMMACK
<L
<A MDLN>
<A SOFTREV>
>
> .
The Host sends this message using the following format:
S1F14 * H->E
<L
<B [1] 00> * COMMACK
<L>
> .
The Equipment always sends the value 0x00 for COMMACK.
In messages received from the Host, COMMACK value 0x00 indicates acceptance of the connect request. Any other
value indicates refusal.
6.11 S1F15 - Request Off-Line
S1F15 W . * H -> E
Host requests the Equipment to go Off-Line.
6.12 S1F16 - Off-Line Acknowledge
S1F16 * H <- E
<B [1] 0x00> . * OFLACK
Equipment Control State transits to Host Off-Line and sends this message in response to S1F15 primary. OFLACK is
always zero.
6.13 S1F17 - Request On-Line
S1F17 W . * H -> E
Host requests the Equipment to go On-Line.
6.14 S1F18 - On-Line Acknowledge
S1F18 * H <- E
<B [1] ONLACK> .
Equipment responds to S1F17 primary in an attempt to go On-Line. Data item ONLACK indicates the success or failure
of the attempt.