STRASBAUGH, INC.
6-10 February 19, 2002 7AF SECS/GEM Interface Ver. 1.9
Strasbaugh Confidential
<U4 REPGSZ> * Reporting Group Size
<L
<U4 SVID> * Status Variable ID
...
>
> .
The Host requests the Equipment to initiate a time driven trace operation.
The Equipment will send trace data using S6F1.
If TRID in S2F23 matches TRID of an existing trace, the existing trace operation is canceled, and replaced by the new one.
Up to four (4) separate TRIDs can be in operation simultaneously.
Within DSPER, must be a valid hour/minute/second format ( hh 0-23, mm 0-59, ss 0-59), and cannot be 000000. The
practical minimum value of DSPER is application dependent.
The Equipment will send the first S6F1 at one time period (DSPER * REPGSZ) after receiving S2F23.
If TOTSMP is zero, then S2F23 is a request to cancel an existing trace. Any trace with the specified TRID is canceled.
REPGSZ minimum value is 1. REPGSZ may not be so large that S6F1 would be a multi-block message. Typical value is
1.
Several SVIDs can be specified if desired. You must not specify so many SVIDs that S6F1 becomes a multi-block
message.
Normally, only Variables of class SV are used in this message. However, any VID of class DV, EC, or SV can be used.
For compatibility with older Host implementations, the Equipment allows the following alternative form for this message,
using an array format:
S2F23 W * H->E
<L [5]
<U4 TRID> * Trace ID
<A 'hhmmss'> * DSPER - Data Sample Period
<U4 TOTSMP> * Total Number of Samples
<U4 REPGSZ> * Reporting Group Size
<U4 SVID ...> * Status Variable ID array
> .
6.26 S2F24 - Trace Initialize Acknowledge
S2F24 * H<-E
<B [1] TIAACK> . * TIAACK - Trace Init. Ack.