EasyManua.ls Logo

Strasbaugh nTellect 7AF - Page 1499

Default Icon
2493 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
STRASBAUGH, INC.
7AF SECS/GEM Interface Ver. 1.9 February 19, 2002 6-9
Strasbaugh Confidential
6-9
If TIMEFORMAT = 1, the format is YYYYMMDDhhmmsscc
YYYY Year, 0000 to 9999
MM Month, 01 to 12
DD Day, 01 to 31
hh Hours, 00 to 23
mm Minutes, 00 to 59
ss Seconds, 00 to 59
cc Centiseconds
When the Equipment receives a good S2F18, it sets its internal clock/calendar. When receiving S2F18, the Equipment
will discard an invalid date or time. For example, if the date is good but the time is bad, the Equipment sets its date but
not its time.
6.23 S2F21 - Remote Command
S2F21 [W] * H->E
<A RCMD> . * Remote command string
Note: This message is only provided for compatibility with non-GEM Hosts.
The Host sends a Remote Command to the Equipment.
The 7AF ignores case when performing validity checks on the RCMD strings.
The Host may optionally set the W-Bit to "1" in S2F21. If so, the Equipment replies with S2F22.
6.24 S2F22 - Remote Command Acknowledge
S2F22 * H<-E
<B [1] CMDA> . * Command Ack. Code
Normal completion returns a zero (0) in CMDA.
A non-zero value for CMDA indicates that the Equipment has rejected the Remote Command.
CMDA Description
0x00 OK. All normal.
0x01 Invalid command. Equipment rejects command
0x02 Cannot perform now. Equipment rejects command.
0x40 Control State is Local. Equipment rejects command.
0x41 Incorrect Process State for this command. Equipment
rejects command.
6.25 S2F23 - Trace initialize send
S2F23 W * H->E
<L [5]
<U4 TRID> * Trace ID
<A 'hhmmss'> * DSPER - Data Sample Period
<U4 TOTSMP> * Total Number of Samples

Table of Contents