EasyManua.ls Logo

Strasbaugh nTellect 7AF - Page 1498

Default Icon
2493 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
STRASBAUGH, INC.
6-8 February 19, 2002 7AF SECS/GEM Interface Ver. 1.9
Strasbaugh Confidential
6.19 S2F15 - New Equipment Constant Send
S2F15 W * H->E
<L
<L [2]
<U4 VID> * Equipment Constant ID
<V>
>
...
> .
The Host sends new values for desired Equipment Constants. Several Equipment Constants can be specified if desired.
Only VIDs of class EC can be used in this message.
6.20 S2F16 - Equipment Constant Send Acknowledge
S2F16 * H<-E
<B [1] EAC> . * Equipment Acknowledge Code
Normal completion returns a zero (0) in EAC. If any ECID or ECV in S2F15 is invalid, then EAC contains a non-zero
value, and the Equipment rejects the entire S2F15. Possible EAC values are:
EAC Description
0x00 OK
0x01 At least one ECID invalid
0x02 Busy, Denied
0x03 At least one ECV out of range
6.21 S2F17 - Date and Time Request
S2F17 W . * H<->E
The Host may send this message at any time to determine the Date and Time base which the 7AF is currently using.
The 7AF sends this message at the request of the operator.
6.22 S2F18 - Date and Time Data
S2F18 * H<->E
<A TIME> . * TIME – Date and Time
This message contains the current Date and Time, specified in either a 12-byte or 16-byte format. The 16-byte format was
defined to support Y2K compatibility, and is supported when the TIMEFORMAT variable (VID 141) is set to “1”. To
maintain compatibility with older systems, the 12-byte format is supported when the TIMEFORMAT variable is set to “0”.
If TIMEFORMAT = 0, the format is YYMMDDhhmmss
YY Year (last two digits), 00 to 99
MM Month, 01 to 12
DD Day, 01 to 31
hh Hours, 00 to 23
mm Minutes, 00 to 59
ss Seconds, 00 to 59

Table of Contents