STRASBAUGH, INC.
7AF SECS/GEM Interface Ver. 1.9 February 19, 2002 6-7
Strasbaugh Confidential
6-7
S1F66 * H<-E
<B [1] 00> . * COMMACK
The Host sends this message using the following format.
S1F66 * H->E
<L
<B [1] 00>
<L>
> .
The Equipment also accepts the following form of this message.
S1F66 * H->E
<B [1] 00> . * COMMACK
The Equipment always sends the value 0x00 for COMMACK.
In messages received from the Host, COMMACK value 0x00 indicates acceptance of the connect request. Any other
values indicate refusal.
6.17 S2F13 - Equipment Constant Request
S2F13 W * H->E
<L
<U4 VID> * Equipment Constant ID
...
> .
The Host requests the VIDs of interest. Several VIDs can be specified if desired.
Normally, only VIDs of class EC (i.e. Equipment Constants) are used in this message. However, any VID of class DV,
EC, or SV can be used.
If S2F13 contains a zero-length list, then the Equipment will report all variables of class EC, in order by VID.
For compatibility with older Host implementations, the Equipment allows the following alternative form for this message,
using an array format:
S2F13 W * H->E
<U4 VID ...> . * Equipment Constant ID
6.18 S2F14 - Equipment Constant Data
S2F14 * H<-E, Multiblock
<L
<V> * Equipment Constant Value
...
> .
The Equipment returns the Equipment Constants in the order requested in S2F13. If any VID specified in S2F13 is
invalid, the corresponding V in S2F14 has the following error format:
<L> * V for Invalid VID