STRASBAUGH, INC.
6-12 February 19, 2002 7AF SECS/GEM Interface Ver. 1.9
Strasbaugh Confidential
6.30 S2F30 - Equipment Constant Namelist Reply
S2F30 * H<-E, Multiblock
<L
<L [6]
<U4 VID> * Equipment Constant ID
<A ECNAME> * Equipment Constant Name
<ECMIN> * ECV Minimum Value
<ECMAX> * ECV Maximum Value
<ECDEF> * ECV Default Value
<A UNITS> * Units of Measure
>
...
> .
The Equipment returns the Equipment Constant descriptions in the order requested in S2F29. If any VID specified in
S2F29 is invalid, the corresponding List in S2F30 has the following error format:
<L> * Instead of L [6]
6.31 S2F31 - Date and Time Send
S2F31 W * H->E
<A TIME> . * TIME – Date and Time
This message contains the current Date and Time, specified in either a 12-byte or 16-byte format. The 16-byte format was
defined to support Y2K compatibility, and is supported when the TIMEFORMAT variable (VID 141) is set to “1”. To
maintain compatibility with older systems, the 12-byte format is supported when the TIMEFORMAT variable is set to “0”.
If TIMEFORMAT = 0, the format is YYMMDDhhmmss
YY Year (last two digits), 00 to 99
MM Month, 01 to 12
DD Day, 01 to 31
hh Hours, 00 to 23
mm Minutes, 00 to 59
ss Seconds, 00 to 59
If TIMEFORMAT = 1, the format is YYYYMMDDhhmmsscc
YYYY Year, 0000 to 9999
MM Month, 01 to 12
DD Day, 01 to 31
hh Hours, 00 to 23
mm Minutes, 00 to 59
ss Seconds, 00 to 59
cc Centiseconds
The Host commands the Equipment to set its Date and Time base to the specified value.