STRASBAUGH, INC.
6-26 February 19, 2002 7AF SECS/GEM Interface Ver. 1.9
Strasbaugh Confidential
6.57 S5F71 - Alarm Report Block Send
S5F71 [W] * H<-E
<L [2]
<U1 0> * ALPY Alarm Priority
<L [1]
<L [4]
<U4 ALID> * ALID - Alarm ID
<BOOLEAN ASTAT> * T = Alarm On
F = Alarm Off
<U4 ASER> * ASER Alarm Serial Number
<A [16] 'YYYYMMDDhhmmsscc'> * CLOCK
>
>
> .
Note: This message is provided only for compatibility with Host computers which support an older version of GEM.
If the Equipment Constant "ConfigAlarms" is set to "1", the Equipment sends S5F71 instead of the normal S5F1 Alarm
Notification Send.
The 7AF reports that an alarm condition has changed.
ALID identifies the Alarm.
ASTAT value is "True" (Non-zero) if this alarm is currently On (Unsafe), or "False" (Zero) if it is currently Off (Safe).
ASER (Alarm Serial Number) is assigned by the Equipment. Its value begins at "1" and is incremented by 1 for each alarm
reported.
ALPY (Alarm Priority) is always zero.
CLOCK indicates the date and time of the alarm change.
Equipment Constant "Wbits5" controls whether the Equipment sends S5F71 with w-bit= "1" (Reply Expected) or "0" (No
Reply Expected).
6.58 S5F72 - Alarm Report Block Acknowledge
S5F72 * H->E
<L> .
The Host acknowledges Alarm Report. This Equipment ignores the data portion of S5F72.
6.59 S5F73 - Alarm Report Block Acknowledge
S5F73 [W] * H<-E
<L [3]
<U4 ALID> * ALID - Alarm ID
<BOOLEAN ASTAT> * T = Alarm On, F = Alarm Off.
<A [16] 'YYYYMMDDhhmmsscc'> * TIMESTAMP
> .