6.54 S5F6 - List Alarm Data
S5F6 * H<-E, Multiblock
<L
<L [3]
<B [1] ALCD> * ALCD - Alarm On/Off and
Severity Code
<U4 ALID> * Alarm ID
<A ALTX> * ALTX - Alarm Text
>
...
> .
The high-order bit of ALCD will be "1" if this alarm is currently On (Unsafe), or "0" if it is currently Off (Safe). The low-
order seven bits of ALCD contain the severity code for this alarm.
For any invalid ALID specified in S5F5, the corresponding entry in S5F6 has the following special error format:
<L [3]
<B> * ALCD - alarm On/Off and Severity
Code
<U4 ALID> * Alarm ID
<A> * ALTX - Alarm Text
>
If S5F5 specified all alarms, S5F6 reports alarms in order by alarm ID.
6.55 S5F7 - List Enabled Alarms Request
S5F7 W . * H->E
The Host requests the Equipment to send the current status of all Alarm IDs which are currently enabled (See S5F3).
6.56 S5F8 - List Enabled Alarm Data
S5F8 * H<-E, Multiblock
<L
<L [3]
<B [1] ALCD> * ALCD - Alarm On/Off and
Severity Code
<U4 ALID> * Alarm ID
<A ALTX> * ALTX - Alarm Text
>
...
> .
The high-order bit of ALCD will be "1" if this alarm is currently On (Unsafe), or "0" if it is currently Off (Safe). The low-
order seven bits of ALCD contain the severity code for this alarm.
S5F8 contains only those ALIDs which are currently enabled for reporting (See S5F3).
S5F8 reports alarms in order by Alarm ID.