If TIMEFORMAT = 1, the format is YYYYMMDDhhmmsscc
YYYY Year, 0000 to 9999
MM Month, 01 to 12
DD Day, 01 to 31
hh Hours, 00 to 23
mm Minutes, 00 to 59
ss Seconds, 00 to 59
cc Centiseconds
The V's appear in the same order they were specified in S2F23.
S6F1 is normally single block. However, if the Host erroneously initiates a multiblock trace using an incorrect S2F23,
S6F1 may be multi-block. The Equipment never sends an Inquire/Grant message preceding S6F1.
Equipment Constant "WBitS6" controls whether the Equipment sends S6F1 with W-Bit "1" (Reply Expected) or "0" (No
Reply Expected).
6.62 S6F2 - Trace Data Acknowledge
S6F2 * H->E
<B [1] 00> . * ACKC6
The Host acknowledges the data. The Equipment ignores ACKC6.
6.63 S6F3 - Annotated Event Report
S6F3 [W] * H<-E, Multiblock
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 DSID> * DSID=RPTID Report ID
<L
<U4 VID> * Variable ID
<V> * Variable Value
>
...
>
>
...
> .
Note: This message is provided only for compatibility with older Host computers which do not support GEM. (See
section 2.7.2, "Gem Configuration".)
If the Equipment Constant "ConfigEvents" is set to "0", the Equipment sends S6F3 instead of the normal S6F13
Annotated Event Report.
A Collection Event has occurred at the Equipment. The Host has enabled event reporting for this CEID (see S2F37). The
Host has set the Equipment constant RpType to "True" (Annotated report format desired). The 7AF sends one or more
Event Reports which the Host has previously linked to that CEID (see S2F35). Each report contains specific Variables
which the Host has previously defined for that Report (See S2F33).