STRASBAUGH, INC.
6-38 February 19, 2002 7AF SECS/GEM Interface Ver. 1.9
Strasbaugh Confidential
If the specified PPID is not found in the library, S7F6 has the following special format:
S7F6 * H<->E
<L> .
If the Equipment receives S7F6 and cannot store the Process Program in its library, the CEID BadDownload is signaled,
with PPChangeName set to the PPID of the requested Process Program. This occurs if the received S7F6 is of the special
"not found" form, if the S7F6 message is not in the expected format, or if an error is detected in PPBODY (for example, a
parameter out of range).
6.89 S7F17 - Process Program Delete
S7F17 W * H->E
<L
<A PPID> * Process Program ID
...
> .
The Host deletes one or more Process Programs from the Equipment library.
If S7F17 contains a zero-length List, the entire library is deleted.
6.90 S7F18 - Process Program Delete Acknowledge
S7F18 * H<-E
<B [1] ACKC7> . * ACKC7 - Acknowledge Code
The Equipment acknowledges the Process Program delete.
ACKC7 Description
0x00 Normal. All specified PPIDs have been deleted.
0x04
Error: At least one specified PPID was not found.
However, correct PPIDs have been deleted from the
Equipment Library
6.91 S7F19 - Process Program Directory Request
S7F19 W . * H->E
The Host requests a directory of the Process Programs currently in the Equipment library.
6.92 S7F20 - Process Program Directory
S7F20 * H<-E
<L
<A PPID> * Process Program ID
...
> .
The Equipment sends a directory of its Process Program library. If the library is empty, the list will be zero length.