Operations and Maintenance Manual Mechanical Maintenance Procedures
Version 1.2 - June 2004 11 - 143
b. If the tension meets the goal, go on to When Satisfactory Adjustment Is
Achieved, below.
c. If the tension needs adjustment, go to the Adjustment Procedure section,
below, to make corrections.
C. ADJUSTMENT PROCEDURE
1. Using a 5/32-in. hex key, loosen the three #10 socket head capscrews at the
top of the spin rinse motor mounting plate by rotating them counterclockwise
to loosen.
2. Slide the motor to reposition it as needed to meet the goal.
3. When the goal has been met, retighten the capscrews to firm by rotating them
clockwise.
4. Recheck the adjustment by repeating Step 2., above in Section B.
a. If the tension meets the goal, go on to When Satisfactory Adjustment Is
Achieved, below.
b. If the tension needs adjustment, repeat the adjustment procedure.
D. WHEN SATISFACTORY ADJUSTMENT IS ACHIEVED
1. Close door 10.