EasyManua.ls Logo

Strasbaugh nTellect 7AF - Page 542

Default Icon
2493 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Strasbaugh nTellect (Model 7AF) Wafer Grinder
14 - 28 Version 1.2 - June 2004
SPIN STATION
SPIN CHUCK UP/DOWN
Cause: Spin station chuck has not moved
into the commanded position.
Resolution: Check spin station chuck
up/down position sensors.
SPIN LID UP/DOWN
Cause: Spin station lid has not moved
into the commanded position.
Resolution: Check spin station lid
up/down position sensors.
SPIN STATION HOME
Cause: The procedure to home the spin
chucks failed.
Resolution:
Retry homing the chucks after all
other axes have been homed.
"Quit" and reenter the homing
screen. Press "Home All".
THICKNESS
THICKNESS LIMIT
Cause:
Wafers were not coarse ground.
Input wafer is too thick.
Incorrect probe reference.
Resolution:
Check feed wafer thickness in recipe.
Check input wafer thickness.
Check probe reference.

Table of Contents