D950 Digital Mixing System
Date printed: 05.12.03 SW V3.3 System Administration 6-27
Different red light sources can be assigned to the same output relay, that is,
whenever the red light condition of any of the sources is TRUE, the relay
will be switched on (logical OR). To switch off a relay, neither of the
paths must be open.
Every red light source can be connected with one of the studio main panels
configured in the monitoring.ini file. It is then possible to trigger the relay
with the manual pushbutton located on the studio main panel.
More information on Signaling Setup can be found in chapter 4.7.6.
LineMic
optional
MicAD
Input channel:
Input selector
Channel mute OFF
Fader ON
Group channel:
Input selector
Channel mute OFF
Fader ON
Master channel:
Input selector
Channel mute OFF
Fader ON
Digital interface
Group bus
Master bus