D950 Digital Mixing System
Date printed: 05.12.03 SW V3.3 System Administration 6-29
; modified sections (JM 13.09.01):
; [CCU_0]
; new downloadfirmware for ccu
; ApplicationFilename=C:\D950SYSTEM\c9503601.pgm
;
; not mandatory if no blocked keys on new AMP required
; [BLOCKED_KEYS]
; NumberOfBlockedAmpKeys= number of blocked keys in new Automation Master Panel (AMP) V3.0
; BlockedAmpKey0= inactive key number 0..51
; [PHYSICAL_UI] actual Desk resources
; NumberOfHDLCMaster= corresponds HDLC Master controllers installed in the Control PC (1..4)
; NumberOf4ChStrips= corresponds to 4-channel strips of the whole D950 System
; Note: NumberOf4ChStrips can be smaller than defined below
; ([4CH_STRIP_NODE_x]), but not greater.
; NumberOf4ChBargraph= corresponds to 4-channel Bargraph of the whole D950 System
; NumberOfCcu= corresponds to Central Control Units of the whole D950 System
; Note: NumberOfCcu can be smaller than defined below
; ([CCU_x]), but not greater.
; NumberOfMpu= corresponds to Multiformat Panning Units of the whole D950 System
; Note: NumberOfMpu can be smaller than defined below
; ([MPU_x]), but not greater.
; NumberOfCas= corresponds to Central Assign Section Units of the whole D950 System
; Note: NumberOfCas can be smaller than defined below
; ([CAS_x]), but not greater.
; IsRotaryResolutionLow= indicates if new Encoders with 40 instead of 100 cycles per Rotation
; are assembled in 4-channel strips (Yes/No dft:No)
; FaderValueWithoutTouch= Allows processing of fader values without preceding fader touch
; (Yes/No dft:No)
; RotaryValueWithoutTouch= Allows processing of rotary values without preceding rotary touch
; (Yes/No dft:No)
; ExtendedHdlcErrMessage= Allows Extended HDCL Error messages readout in D950system.log
; (Yes/No dft:Yes)
[PHYSICAL_UI]
NumberOfHDLCMaster=1
NumberOf4ChStrips=4
NumberOf4ChBargraph=4
NumberOfCcu=1
NumberOfMpu=1
NumberOfCas=1
IsRotaryResolutionLow=No
FaderValueWithoutTouch=No
RotaryValueWithoutTouch=No
ExtendedHdlcErrMessage=Yes
; [4CH_STRIP_NODE_0] first 4-ch. strip with logical Node No. (starting with 0)
; MasterAddr= connected to HDLC Master x (0..NumberOfHDLCMaster-1)
; HDLC master address 0 = IP module A
; HDLC master address 1 = IP module B
; HDLC master address 2 = IP module C
; HDLC master address 3 = IP module D
; HDLCAddr= corresponds to Strip Node HDLC address
; (starting with 0, 4, 8..60 in decimal)
; LACPPresent= indicates, if LACP (16 Rotaries, displays etc.) is present (Yes/No dft:No)
; BargraphPresent= indicates, if 4-ch. Bargraph is present (Yes/No dft:No)
; NewBargraph= indicates, if new 2-Sandwich PCB Bargraph is present (Yes/No dft:No)
; BargraphHDLCAddr= corresponds to Bargraph Node HDLC address
; (same as Strip Node Addr., starting with 0, 4, 8..60 in decimal)
; DeskLocation= corresponds to the physical location on the Desk (Left/Right
dft:Left)
; ApplicationFilename= location and name of Application to download (k9404902.pgm for D950 Classic,
; k9504902.pgm for D950 M2,
; f9504902.pgm for D950 Fader only)