EasyManua.ls Logo

Studer D950 - Page 563

Studer D950
648 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D950 Digital Mixing System
Date printed: 05.12.03 SW V3.3 System Administration 6-33
[LOG_CTRL_GRP_3]
NumberOf4ChStrips =
NumberOfMpu=
4ChStripNodeAssign0=
4ChStripNodeAssign1=
... ..... .... .
4ChStripNodeAssignX=
CCUNodeAssign=
MPUNodeAssign0=
IsLeftJoystickActiveOnMPU0=
IsRightJoystickActiveOnMPU0=
; [LEVELS_dB] System Level Section
; NominalLevel= Nominal System level in dB
; Headroom= Headroom definition in dB (0/3/4/6/9/10/12/15)
; VULead= Lead of Bargraph VU mode in dB (0/2/3/4/6/8)
; IsVUDecayLow= Sets VU Decay time to same as PPM Decay time
; (Yes/No; dft:no)
; Note: Clip Level (0 dB FS) = NominalLevel + Headroom must be 0..26
; due to external A/D D/A devices (MicAD, MultiDAC etc.)
[LEVELS_dB]
NominalLevel=6
Headroom=9
VULead=4
IsVUDecayLow=No
; [TIMES_ms] System Times Section
; CasPPMDecay= CAS L/R Level Bargraph decay time in ms (dft: 2500 ms)
; CasPeakHold= CAS L/R temporary Peak hold time in ms (dft: 3000 ms)
; CasOVRHold== CAS L/R temporary OVR Led hold time in ms (dft: 5000 ms)
; Note: min. time resolution of CAS is 10 ms; finer settings are truncated.
; CasPPMDecay time is set for the whole bargraph length (51 active Leds);
; with a min. resolution of 10 ms per segment, only increments of 50*10ms = 0.5 sec
; make sense;
[TIMES_ms]
CasPPMDecay=2500
CasPeakHold=3000
CasOVRHold=5000

Table of Contents

Related product manuals