D950 Digital Mixing System
Date printed: 03.09.03 SW V3.3 Getting started 2-43
TB INT
1
SEND
0
8
9
5
RETURN
4
3
2
1
0
6
7
8
9
TALKBACK
5
BUS
3
2
4
TO:
DIRECT
6
7
5
LEVEL
PFL/SOLO
2
0
1
3
4
7
9
8
6
GROUPAUX
Σ
HEADPHONES
5
LEVEL/BALANCE
2
1
0
3
L
4
7
9
8
6
R
CR
INJ.
INTER
LOCK
SEL
SAFE
BROAD
30Hz
AUTO
TB
CUE
TB
PFL/
RET.
TB
INTERN
EXT. 1
TB
1
2
RET.
AIR
ON
PLACE
IN
SOLO
RESET
SOLO
PFL/
SEL
CR
SEL
STUDIO
SOLO
PFL/
CUT
LOCK
TB
EXT. 2 EXT. 3
OMNI
SOLO
PFL
TALKBACK (communication functions):
RETURN 1/2
These keys select one of two switchable talkback return signals.
AUTO CUE
This key provides activation of the TB system from an external control
signal.
ON AIR
This key provides Safe mode activation – SOLO IN PLACE and
talkback to the master buses are disabled.
PFL/BROAD
When activated, this function ensures that any channel PFL is turned
off when the channel fader is opened – Broadcast Mode.
TB LOCK
When activated, this function allows the talkback keys to be changed
from momentary to latching function.
TB INT. TO:
This key allows Desk-internal talkback to be routed to whichever of the
following targets is selected: BUS, DIRECT, AUX, GROUP, Σ (mas-
ter).
TB EXT 1...3
This key controls Talkback routing to up to three separate external desti-
nations.
30 Hz
This key adds a 30 Hz tone to the internal talkback signal.
OMNI
This key activates all configured talkback send destinations at the same
time.
SEND
This is a Level control for talkback send.
RETURN
This is a Level control for the Return 1 and 2 signals to talkback.