Chapter 4 – General Configuration
Firmware Version 3/4.31.37
Blnd Adj Start Vol
(Excluding SMP & SCS)
Blend Adjust Start Volume applies to ratio blending only. After the volume specified in
this parameter has been delivered, the system will start adjusting the ratio of the
blend, when it is found to deviate from the tolerance by the amount specified in the
Blend Adjust Deviation Percentage parameter. The deviation must occur for the
period specified by the Blend Adjust Time parameter before any adjustments are
attempted. This parameter is intended to give the flows from the multiple meters an
opportunity to stabilize after an initial start from zero flow. No blend ratio adjustments
are made until after this volume has been delivered. This setting should be
configured to be greater than the Low Flow Start Volume and less than the Blend
Check Start Volume, so that adjustments can begin after the transition to High Flow.
Blnd Adj Restart Vol
(Excluding SMP & SCS)
Blend Adjust Restart Volume applies to ratio blending only. After the volume
specified in this parameter has been delivered, the system will begin adjusting the
ratio of the blend, when it is found to deviate from the tolerance by the amount
specified in the Blend Adjust Deviation Percentage parameter. The deviation must
occur for the period specified by the Blend Adjust Time parameter before any
adjustments are attempted. This parameter is intended to give the flows from the
multiple meters an opportunity to stabilize after a Restart from zero flow. No blend
ratio adjustments are made until this volume has been delivered. This setting should
be configured to be greater than the Low Flow Restart Volume and less than the
Blend Check Restart Volume, so that adjustments can begin after the transition to
High Flow.
Blnd Adj Dev %
(Excluding SMP & SCS)
Blend Adjust Deviation Percentage applies to ratio blending only. The system will
begin adjusting the ratio of the blend when it is found to deviate from the tolerance by
the amount specified in this parameter. The deviation must occur for the period
specified by the Blend Adjust Time parameter before any adjustments will be
attempted.
Blnd Adj Dev Vol
(Excluding SMP & SCS)
Blend Adjust Deviation Volume applies to ratio blending only. The system will begin
adjusting the ratio of the blend, when it is found to deviate from the specified
tolerance by the volume entered in this parameter. The deviation must occur for the
period specified by the Blend Adjust Time parameter before any adjustments will be
attempted.
Blnd Adj Time
(Excluding SMP & SCS)
Time period, in seconds, during which a deviation in the blend ratio tolerance must
occur in order for a ratio adjustment to be made. (See parameters Blnd Adj Dev%
and Blnd Adj Restart Vol.)
The low flow rate which will be used during the proving mode
Minimum preset volume allowed.
When non-zero and operating in stand-along mode, this value will be the default
preset volume to load. If there is only one authorized product, no prompting will
occur.
Maximum preset volume allowed.
When enabled, if operating in stand-alone mode, a transaction is authorized, and the
program mode switch is inactive, the system will attempt to auto authorize the batch.
If only one product is authorized to be loaded on this arm and the default preset
volume is valid, no prompting will occur.