Chapter 9 – Weights & Measures
293
Firmware Version 3/4.31.37
Table
Description
ASTM1250-
2004 Table 60D
This table provides CTL factors for correcting volumes of lube oils at observed temperatures
to the volume at 20ï‚° C. Use this table if the following conditions exist.
ï‚· The liquid is a lube oil
ï‚· Density @ 20ï‚° C is known
ï‚· Reference Temperature is 20ï‚° C
After selecting this table, enter the Density of the liquid at 20ï‚° C. The valid range of Density
is from 800-1064 kg/m3. Test temperatures can be entered on this screen that will calculate
a CTL based on the test temperature and the Density. The test temperature and Calculated
CTL are for informational purposes and will not be used in calculations during operations.
ASTM1250-
2007 Table 60E
This table provides CTL factors for correcting volumes of light hydrocarbons at observed
temperatures to the volume at 20ï‚° C. Use this table if the following conditions exist.
ï‚· The liquid is a NGL or LPG (propane)
ï‚· Density at 20ï‚° C is known
ï‚· Reference Temperature is 20ï‚° C
After selecting this table, enter the Density of the liquid at 20ï‚° C. The valid range of Density
is from 350-688. Test temperatures can be entered on this screen that will calculate a CTL
based on the test temperature and the Density. The test temperature and Calculated CTL
are for informational purposes and will not be used in calculations during operations.
ASTM1250-
2004 Table 60X
This table provides the CTL factors of a petroleum product at observed temperatures and
Density. This table allows specifying the commodity being measured, the reference
temperature, and units of measure for density, pressure, and temperature
ASTM1250-
2004 Table 53A
This table is used to correct observed density at the observed temperature to a density at
15ï‚° C. When this table is activated, the corrected density is then automatically used in Table
54B, which provides CTL factors for correcting volumes of gasolines at observed
temperatures to the volume at 15ï‚° C. Use this table if the following conditions exist.
ï‚· The liquid is crude oil
ï‚· Observed Density is to be corrected to 15ï‚° C and used in Table 54B
ï‚· Reference Temperature is 15ï‚° C
After selecting this table, enter the Density of the liquid at the observed temperature. The
valid range of Density is from 610-1075 kg/m3. Test temperatures can be entered on this
screen that will calculate a CTL based on the test temperature and the Density. The test
temperature and Calculated CTL are for informational purposes and will not be used in
calculations during operations.
ASTM1250-
2004 Table 53B
This table is used to correct observed density at the observed temperature to a density at
15ï‚° C. When this table is activated, the corrected density is then automatically used in Table
54B, which provides CTL factors for correcting volumes of gasolines at observed
temperatures to the volume at 15ï‚° C. Use this table if the following conditions exist.
ï‚· The liquid is a refined product
ï‚· Observed Density is to be corrected to 15ï‚° C and used in Table 54B
ï‚· Reference Temperature is 15ï‚° C
After selecting this table, enter the Density of the liquid at the observed temperature. The
valid range of Density is from 653-1075 kg/m3. Test temperatures can be entered on this
screen that will calculate a CTL based on the test temperature and the Density. The test
temperature and Calculated CTL are for informational purposes and will not be used in
calculations during operations.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech Systems MultiLoad II and is the answer not in the manual?

Toptech Systems MultiLoad II Specifications

General IconGeneral
BrandToptech Systems
ModelMultiLoad II
CategoryControl Unit
LanguageEnglish

Related product manuals