Chapter 9 Weights & Measures
294
Firmware Version 3/4.31.37
Table
Description
ASTM1250-
2004 Table 53D
This table is used to correct observed density at the observed temperature to a density at
15 C. When this table is activated, the corrected density is then automatically used in Table
54B, which provides CTL factors for correcting volumes of gasolines at observed
temperatures to the volume at 15 C. Use this table if the following conditions exist.
The liquid is a lube oil
Observed Density is to be corrected to 15 C and used in Table 54B
Reference Temperature is 15 C
After selecting this table, enter the Density of the liquid at the observed temperature. The
valid range of Density is from 800-1064 kg/m3. Test temperatures can be entered on this
screen that will calculate a CTL based on the test temperature and the Density. The test
temperature and Calculated CTL are for informational purposes and will not be used in
calculations during operations.
ASTM1250-
2007 Table 53E
This table provides density at 15 C of light hydrocarbons at observed temperature and
density. Use this table if the following conditions exist.
The liquid is a NGL or LPG (propane)
Current Temperature and Density is available.
Density at 15 C is unknown
Reference Temperature is 15 C
Test temperatures and densities can be entered on this screen that will calculate the
corrected density at the test temperature and density. The test temperature, density and
Calculated corrected density at 60 F are for informational purposes and will not be used in
calculations during operations.
Note: This table will not produce a CTL value, but this table may be used by other tables
ASTM1250-
2004 Table 59A
This table is used to correct observed density at the observed temperature to a density at
20 C. When this table is activated, the corrected density is then automatically used in Table
54B, which provides CTL factors for correcting volumes of gasolines at observed
temperatures to the volume at 20 C. Use this table if the following conditions exist.
The liquid is crude oil
Observed Density is to be corrected to 20 C and used in Table 54B
Reference Temperature is 20 C
After selecting this table, enter the Density of the liquid at the observed temperature. The
valid range of Density is from 610-1075 kg/m3. Test temperatures can be entered on this
screen that will calculate a CTL based on the test temperature and the Density. The test
temperature and Calculated CTL are for informational purposes and will not be used in
calculations during operations.
ASTM1250-
2004 Table 59B
This table is used to correct observed density at the observed temperature to a density at
20 C. When this table is activated, the corrected density is then automatically used in Table
54B, which provides CTL factors for correcting volumes of gasolines at observed
temperatures to the volume at 20 C. Use this table if the following conditions exist.
The liquid is a refined product
Observed Density is to be corrected to 20 C and used in Table 54B
Reference Temperature is 20 C
After selecting this table, enter the Density of the liquid at the observed temperature. The
valid range of Density is from 653-1075 kg/m3. Test temperatures can be entered on this
screen that will calculate a CTL based on the test temperature and the Density. The test
temperature and Calculated CTL are for informational purposes and will not be used in
calculations during operations.