EasyManuals Logo

Toptech Systems MultiLoad II User Manual

Toptech Systems MultiLoad II
515 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #299 background imageLoading...
Page #299 background image
Chapter 9 – Weights & Measures
299
Firmware Version 3/4.31.37
d) Find the parameter, Pressure Sensor. This parameter should already be enabled if the pressure
calibration step has been performed.
e) Find the Default Pressure parameter. Configure this parameter for 999.9. Do not adjust this value unless
the pressure transmitter is undergoing maintenance.
f) Find the parameter Pressure @ 4mA. Enter the pressure that will represent the lowest pressure value
measured by the sensor.
g) Find the parameter Pressure @ 20mA. Enter the pressure that will represent the highest pressure value
measured by the sensor.
h) Press the EXIT key until the Main Menu is displayed. Enter the Configuration/Equipment Setup/Meter
menu. Select the appropriate Preset and Meter.
i) Find the parameter Alarm Low Pressure. Enter the pressure that represents the lower pressure limit of the
API table in use.
j) Find the parameter Alarm High Pressure. Enter the pressure that represents the highest pressure limit of
the API table in use.
9. Configure for Default Pressure
When the pressure transmitter is undergoing maintenance, the observed pressure can be manually entered
for use by the API table.
a) Enter the program mode at the MultiLoad II. Select the Weights & Measures/Meters menu. Then select
the appropriate preset and meter.
b) Find the parameter, Pressure Sensor. Set the parameter to Disabled.
c) Find the Default Pressure parameter. Enter the pressure that is observed at the flow meter.
d) When the pressure transmitter is ready to be placed back in service, re-enable the pressure transmitter
parameter and return the default pressure to 999.9.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech Systems MultiLoad II and is the answer not in the manual?

Toptech Systems MultiLoad II Specifications

General IconGeneral
BrandToptech Systems
ModelMultiLoad II
CategoryControl Unit
LanguageEnglish

Related product manuals