Chapter 9 – Weights & Measures
308
Firmware Version 3/4.31.37
D1=Volume weighted average Density measured while flowing Regular
OR specified for meter M1
Dr=Density specified for the Regular component
Nrm=Net volume loaded for the Regular Meter
VCFr=API Correction Table for Regular
Mrm=Mass loaded for the Regular Meter
Regular product (Component Level) values are reported as:
Gr=Grm
Tr=Trm
Dr=Dr’ OR Drm
Nr=Nrm
Mr=Mrm
Where: Gr=Gross volume loaded for the Regular component
Tr=Temperature for the Regular component
Dr=Density for the Regular component
Dr’=Density specified for the Regular component
Nr=Net volume loaded for the Regular component
Mr=Mass loaded for the Regular component
Premium meter (Meter Level) values are reported as:
Gpm=M1
Tpm=T1
Dpm=D1 OR Dp
Npm=Gpm*VCFp(Tpm,Dpm)
Mpm=Npm * Dpm OR Mpm=Gpm * D1
Where: Gpm=Gross volume loaded for the Premium Meter
M1=Gross volume reported by meter M1 while flowing Premium
Tpm=Temperature for the Premium Meter
T1= Volume weighted average temperature reported by probe T1 while flowing Premium
Dpm=Density for the Premium Meter
D1=Volume weighted average Density measured while flowing Premium
OR specified for meter M1
Dp=Density specified for the Premium component
Npm=Net volume loaded for the Premium Meter
VCFp=API Correction Table for Premium
Mpm=Mass loaded for the Premium Meter
Premium product (Component Level) values are reported as:
Gp=Gpm
Tp=Tpm
Dp=Dp’ OR Dpm
Np=Npm
Mp=Mpm
Where: Gp=Gross volume loaded for the Premium component
Tp=Temperature for the Premium component

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech Systems MultiLoad II and is the answer not in the manual?

Toptech Systems MultiLoad II Specifications

General IconGeneral
BrandToptech Systems
ModelMultiLoad II
CategoryControl Unit
LanguageEnglish

Related product manuals