Chapter 16 Firmware Revision History
433
Firmware Version 3/4.31.37
Added additive calibration logic to prevent block valve from opening unless
injector is shared.
Added a flush volume reset after calibration to prevent flush alarm.
Updated clock setup to show time/date in real time.
11/03/06 ML, ML1, SMP 3.26 WJP
Added interface to use 4-20mA input on I/O Board or FCM II for Pressure and
Density Inputs.
Added screensaver backlight control logic to dim backlight when idle.
Added a new parameter, R046-screensaver_seconds with a default of 10 minutes.
Added a new parameter, R047-screensaver_brightness_pct with a default of 50.00%.
11/06/06 ML, ML1, SMP 3.26 WJP (released to production)
11/17/06 2.27 WJP
CAR #226 - Add service to background tasks in close_transaction_header to allow
COM and prevent the WDT from causing a reboot while processing transactions with a
very large number of details (>100).
11/21/06 2.27 WJP (released)
CAR #233 - Force all “unused”/”future use” parameters to zero, and log when a
parameter change occurs.
CAR #234 - Correct time edit position on the screen.
11/29/06 2.27 WJP (released to measurement Canada)
(Req. of Measurement Canada) Added vapor pressure to component status display.
(Req. of Measurement Canada) Added bay configuration parameter "Canada API
Limits" to extend low temps down to -40C on tables 54A, 54B (54BC removed), 54C,
54D.
Corrected bug in conversion from 4-20ma to pressure or temperature that caused
value to loop around.
(Req. of Measurement Canada) Limit 4-20mA pressure input to 0 to 4000 Kpa/PSI,
instead of the 9999.
Extend pressure offset from +/- 3.00 to +/- 30.00 Kpa/PSI.
(Req. of Measurement Canada) Changed the stand alone BOL to include "(Net) Volume
corrected to Vapor Pressure 15C" instead of "Net values corrected to 15C".
(Req. of Measurement Canada) Changed the preset control screen to include
"GALLONS Volume corrected to 60 F" instead of "GALLONS corrected to 60 F".
Fixed bug with uninitialized new_hazidx in ticket printing routine that caused
application to halt.
01/05/07 WJP
Changed SMP normal fonts from 20 col to 40 col. This includes all standalone
prompting as well as host driven prompts.
01/18/07 WJP
Added component_current_temp_hunds, component_current_press_hunds and
component_current_density_tenths to real time structure.
01/18/07 3.27.01 WJP
Added minor version number to firmware version. xx.yy.zz
Updated boot screen to display minor version number and firmware build date.
Added UTF-8 terminal support.
Updated R000 to include minor version number.
Updated ditto register to return utf8 characters if displayed.
Extend picklist register to handle UTF8 characters.
Added Unicode diagnostic screen to view available CJK characters.
Updated firmware version to 3.27.01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech Systems MultiLoad II and is the answer not in the manual?

Toptech Systems MultiLoad II Specifications

General IconGeneral
BrandToptech Systems
ModelMultiLoad II
CategoryControl Unit
LanguageEnglish

Related product manuals