EasyManua.ls Logo

Toptech Systems MultiLoad II - Page 472

Toptech Systems MultiLoad II
515 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 16 Firmware Revision History
472
Firmware Version 3/4.31.37
03/07/2013 PS
Enhancement of Custom Logic supports now Temperature, BSW, Gravity, Relative
Density, Density, Pressure, Volumes
Enhancement of Custom Logic supports now Timers Start and Stop Delay.
03/07/2013 WJP
Added display of Battery Voltage and Temperature on RCU Diagnostics screen (only
if CPU board supports the feature).
03/08/2013 PS
Enhancement of Register800 to always transaction read of
api_expansion_coef_tenths, corrected_densitygravity, volume_correction_factor,
bsw_hund, alibilog_alarm
03/08/2013 PS
Added Bay Number to the Web-Interface
03/11/2013 PS
Fix Ticket Print: Measure used was on totalizer line correct for gross , but
incorrect for net.
Also allow totalizer to be shown with max value of 999999999
Fix Measure used for Additive Totalizer Line was missing
03/12/2013 PS
Added in Custom Logic the State for Preset,Meter,Component (High Flow, Low Flow,
....)
Added in Custom Logic under Rcu Real Time Parameters the Date and Time value
03/12/2013 WJP
Corrected bug on SMP firmware builds where the editing of parameters on the RCU
General screen edited the wrong parameter.
03/12/2013 WJP
Update TDS 3po checksum routine to stop converting all incoming and outgoing data
to upper case.
03/18/2013 WJP
Corrected bug (may have been created on 5/17/2011) in processing and prompting
for PIN numbers when processing mode is set to Stand-Alone.
03/19/2013 WJP
Added ability to support two different serial ports set to host mode.
03/21/2013 WJP
Added MRTDpppddd command to directly read the transaction details, for a
specified preset, archived after clearing each batch.
03/29/2013 WJP
Added Batch Number (1-9,999,999) to the transaction archive details.

Table of Contents

Related product manuals