Chapter 16 Firmware Revision History
493
Firmware Version 3/4.31.37
Fix so that Avg. BSW is still calculated even if BSW goes out of range but hasn't
gone into Alarm yet.
Fix Preset Status Screen so that the current BSW value is always displayed, even
if product is not flowing through the meter, when Diverting is enabled.
7/31/2014 PS
Enhancement restrict webserver only to TLS1v2.
Added new Sampler level New configuration level for sampler parameters.
New Custom Logic sampler level. Real-time parameters, Real time alarms, real time
values.
New Alarm configuration level for Samplers.
Added all new sampler parameters to communication protocol.
Added new sampler real-time screen to loading screen logic.
Added real-time sampler totalizers.
Added new sampler diagnostic screen.
Added: Authorization of Sampler.
Added communication registers to access MTK (tank) and MSI (sampler) data.
8/01/2014 MS
Fix: Cleaned up meter diagnostics bug for valve timing set.
8/1/2014 WJP
Updated product logo.
8/5/2014 MS
Enhancement: Added SSL to network sockets. Excluding printer sockets.
Fix: Move 3p0 code to use network functionality.
8/6/2014 PS
Enhancement: The Additive Status Screen will be not shown when no additive is
configured.
Enhancement: The Sampler Status Screen will be not shown when no sampler is
configured.
Enhancement: Additives and Samplers cannot share the same fcm number and port
configuration.
Added new R120 register to read real-time sampler totalizers.
Added to the MRS communication command the sampler gross thousand real-time value
and also the current real-time sample value.
8/8/2014 PS
Enhancement: SCS Build:Blending type will only support watercut.
Enhancement: SCS Build will have no Blending sub menu.
8/11/2014 PS
Enhancement: All Builds of MultiLoad family will not show entered preset value or
remaining volume if preset is 9999999 (7 9's).
8/14/2014 TF
Added eMail feature. The MultiLoad can now send an eMail notification if an alarm
has been tripped or cleared.
A From eMail address, To eMail address, and the domain name of the eMail server
must be entered in correctly.
8/15/2014 TF
Fix Modbus Registers for updating all alarm parameters for all levels. Previously
would not be able to update Alarm to Host, FCM Address, and Batch Alarm Mask
parameters via Modbus.